Power Quality

Transformers

Dry-type transformers specified against the harmonic profile of the real load, not the nameplate.

Modern loads are not linear. Variable-speed drives, switch-mode supplies and LED drivers push distortion back onto the distribution system, and a transformer specified as though they did not exist runs hot, loses efficiency and ages early. Access specifies transformers against what the load actually does.

What we supply

  • Harmonic mitigating transformers
  • Ultra-efficient transformers (CSL3, CSL3 Plus, CSL4)
  • Medium voltage power transformers
  • Low voltage high efficiency transformers
  • General purpose transformers
  • Three phase to single phase converters
A PQI harmonic mitigating distribution transformer shown twice — closed in its cabinet, and open to reveal the copper windings and terminal connections inside
The lines

Who we represent for transformers

The outcome

Specified correctly, supported for its lifecycle.

The right transformer runs cooler, wastes less and lasts longer — and in a harmonic-heavy facility, the efficiency difference between a general purpose unit and a mitigating one is large enough to show up on the bill rather than only in the calculation.

Beyond the box

How we support it

Power Systems

Resilient power from the service entrance to the load — sized, conditioned, and backed up so critical loads remain protected through power disturbances and outages.

  • Generators & automatic transfer switches (ATS)
  • UPS systems & power conditioning
  • PDUs, modular busway & distribution
  • Surge protection & DC power plants
Explore more

Other equipment

See all equipment

Uninterruptible Power Supplies

UPS systems from single-rack to multi-megawatt — sized, installed and maintained so the load never sees the blip.

  • Fixed capacity single phase
  • Centralized, modular single phase
  • Data center and facility 3-phase
  • Battery and flywheel energy storage

Generators & Transfer Switches

Standby generation and the transfer equipment that decides whether the facility rides through an outage.

  • Diesel standby generators
  • Natural gas and bi-fuel generators
  • Automatic transfer switches
  • Static and static bus transfer switches

Busway & Powerbars

Overhead and modular busway that lets a data hall change shape without an electrician rebuilding the branch circuits.

  • Busbar and BusPlug
  • Modular busway
  • Overhead powerbars
  • High-power bar

Let’s talk about what can’t go down.