Precision Cooling & Thermal Management

Computer room cooling that holds tight tolerances continuously, rather than comfort cooling asked to do a job it was not built for.

Comfort air conditioning is designed to make a room pleasant for people over a working day. Precision cooling is designed to hold temperature and humidity inside a narrow band, continuously, for equipment that does not tolerate drift. Access engineers the second kind — in-row, up/down flow, ceiling and wall mounted, and self-contained.

What we supply

  • In-row cooling
  • Small-medium up/down flow
  • Large up/down flow
  • Ceiling suspended
  • Wall mounted
  • Self-contained racks
  • Free cooling and economiser systems
A Vertiv Liebert VRC rack-mounted cooling unit, its perforated front panel facing the camera against white
The lines

Who we represent for precision cooling & thermal management

The outcome

Specified correctly, supported for its lifecycle.

Matched to the load and laid out with the airflow in mind, precision cooling holds the envelope your equipment was warranted against — and with economiser operation it does so on outside air for a large part of the year in this climate, which is where the running cost comes down.

Beyond the box

How we support it

HVAC & Thermal

Precision cooling and air management that holds tight tolerances where heat is the enemy of uptime.

  • Precision & computer-room air conditioning (CRAC/CRAH)
  • Air handling & heat rejection
  • Data-center thermal management & containment
  • Commercial & industrial HVAC

Monitoring

Continuous eyes on every critical system — connected assets, real-time telemetry and alarms that reach a human with somewhere to go.

  • Connected assets across mixed manufacturers
  • Real-time telemetry and condition data
  • Alarm management, escalation and notification
  • Analytics, trending and lifecycle intelligence
Explore more

Other equipment

See all equipment

Uninterruptible Power Supplies

UPS systems from single-rack to multi-megawatt — sized, installed and maintained so the load never sees the blip.

  • Fixed capacity single phase
  • Centralized, modular single phase
  • Data center and facility 3-phase
  • Battery and flywheel energy storage

Generators & Transfer Switches

Standby generation and the transfer equipment that decides whether the facility rides through an outage.

  • Diesel standby generators
  • Natural gas and bi-fuel generators
  • Automatic transfer switches
  • Static and static bus transfer switches

Busway & Powerbars

Overhead and modular busway that lets a data hall change shape without an electrician rebuilding the branch circuits.

  • Busbar and BusPlug
  • Modular busway
  • Overhead powerbars
  • High-power bar

Let’s talk about what can’t go down.